EUCLID: Data Handling Architecture and CFDP Tailoring

14 Feb 2014, 11:00
30m
Newton 2 (ESTEC)

Newton 2

ESTEC

ESTEC, Keplerlaan 1, 2200 AG Noordwijk ZH, Netherlands

Speaker

Mr Antonio Tramutola (Thales Alenia Space)

Description

Euclid satellite shall provide storage capability up to 850Gbits per day of scientific data acquired from NISP and VIS instruments. As a consequence, taking into account autonomy requirements, a Mass Memory Unit with storage capacity of 4Tbits has been specified. TM data are stored in files, thus MMU implements a file system structured in two levels of directories. The MMU has also the capability to downlink files to ground station via CFDP protocol through direct K band link. File uplink is possible through CDMU via Xband using CFDP as well. Communication between CDMU and MMU has been specified via MIL-STD-1553B bus to exchange files data and in general TC and TM. This peculiar implementation of on-board data management and ground communication has required a tailoring of the standard CCSDS CFDP protocol.